2 Installation
2.1.3 Installation Conditions for Applicable Standards
2-4
• Mounting Near a Vibration Source
To prevent vibration from being transmitted to the SERVOPACK, install a vibration
isolator underneath the SERVOPACK.
• Mounting to a Location Exposed to Corrosive Gas
Take measures to prevent exposure to corrosive gas. Corrosive gases will not imme-
diately affect the SERVOPACK, but will eventually cause electronic components and
contactor-related devices to malfunction.
• Other Locations
Do not mount the SERVOPACK in locations subject to high temperatures, high
humidity, dripping water, cutting oil, dust, iron filings, or radiation.
Note: When storing the SERVOPACK with the power OFF, store it in an environment with the
following temperature and humidity:
• -20
°C to +85°C, 90% RH or less. (with no condensation)
2.1.3 Installation Conditions for Applicable Standards
Applicable
Standards
UL508C
EN50178, EN55011 group1 class A, EN61000-6-2, EN61800-3, EN61800-
5-1, EN954-1, IEC61508-1 to 4
Operating
Conditions
Overvoltage Category: III
Pollution degree: 2
Protection class: IP10
Installation
Conditions
UL Standard and Low Voltage Directive:
Satisfy the conditions outlined in
Σ
-V Series AC SERVOPACK SGDV Safety
Precautions (No.: TOBP C710800 10)
EMC Directive:
Certification is required after installation in the user’s machine under the
conditions outlined in 2.5 EMC Installation Conditions of this manual.