Yaskawa Sigma I to Sigma-5 Conversion Guide User Manual
Page 35

35/47
Comparison between
SGDB-□□□D type
and SGDV type
Terminal No.
SGDB typeSGDV typeTerminal Marking Function
50pin
50pin
1
1 SG
Signal Ground
2
2 SG
Signal Ground
3
3 PL1
Battery for open collector reference
4
4 SEN
SEN signal input
5
5 V-REF
Speed reference input
6
6 SG
Signal Ground
7
7 PULS
Reference pulse input
8
8 /PULS
Reference pulse input
9
9 T-REF
Tordque reference input
10
10 SG
Signal Ground
11
11 SIGN
Reference code input
12
12 /SIGN
Reference code input
13
13 PL2
Battery for open collector reference
14
14 /CLR
Clear input
15
15 CLR
Clear input
16
- TRQ-M
Torque monitor
17
- VTG-M
Speed monitor
18
18 PL3
Battery for open collector reference
19
19 PCO
PG frequency dividing output C-phase
20
20 /PCO
PG frequency dividing output C-phase
21
21 BAT /BAT(+)
Battery (+)
22
22 BAT0 / BAT(-)
Battery (-)
23
- +12V
Battery for analog refernce
24
- -12V
Battery for analog refernce
25
25 /V-CMP//COIN Speed match detection output
26
26 /V-CMP//COIN Speed match detection output
27
27 /TGON+
Rotating detection output
28
28 /TGON-
Rotating detection output
29
29 /S-RDY+
Servo-ready output
30
30 /S-RDY-
Servo-ready output
31
31 ALM+
Servo alarm output
32
32 ALM-
Servo alarm output
33
33 PAO
PG frequency dividing output A-phase
34
34 /PAO
PG frequency dividing output A-phase
35
35 PBO
PG frequency dividing output B-phase
36
36 /PBO
PG frequency dividing output B-phase
37
37 ALO1
Alarm code output
38
38 ALO2
Alarm code output
39
39 ALO3
Alarm code output
40
40 /S-ON
Servo ON inuput (*2)
41
41 /P-CON
P operation input (*2)
42
42 P-OT
Forward drive prohibit input (*2)
43
43 N-OT
Reverse drive prohibit input (*2)
44
44 /ALMRST
Alarm reset input
45
45 /P-CL
Forward side external torque limit input
46
46 /N-CL
Reverse side external torque limit input
47
47 +24 VIN
External power supply input
48
- PSO
S-phase signal output
49
- /PSO
S-phase signal output
50
- FG
Frame Ground
(*2): The sequence I/O is factory setting
The allocation change is possible by using the user parameter in ∑-V, but not in ∑ series
(*3):Change the setting of one of three factory setting output signals by user parameter if
needed