Wiring diagram, Electrical installation 2 - 20 – Yaskawa E7B Drive Bypass User Manual
Page 58

Electrical Installation 2 - 20
Wiring Diagram
(1)
(2)
(3)
(4)
(5)
(6)
(T2)
(L2)
(T1)
(L1)
(T3)
(L3)
(1)
(2)
(1)
(2)
(1)
(2)
(T2)
(L2)
(T1)
(L1)
(T3)
(L3)
C2
C1
B2
A2
B1
A1
(2)
(4)
(6)
(1)
(3)
(5)
(95)
(96)
(T2)
(L2)
(T1)
(L1)
(T3)
(L3)
(T2)
(L2)
(T1)
(L1)
(T3)
(L3)
(2)
(4)
(6)
(1)
(3)
(5)
(95)
(96)
(T2)
(L2)
(T3)
(L3)
(T1)
(L1)
(2)
(4)
(6)
(1)
(3)
(5)
(1)
(2)
(1)
(2)
(1)
(2)
(95)
(96)
(95)
(96)
(2)
(4)
(6)
(1)
(3)
(5)
(1)
(2)
(1)
(2)
(1)
(2)
L1/A1
L1/A2
L2/B1
L2/B2
L3/C1
L3/C2
GND1
GND2
C2
C1
B2
A2
B1
A1
EG
+1
+2
MB
MC
MA
M1
M2
M3
M4
S1
S3
SC
S4
S5
SN
L1
L2
L3
T1
T2
T3
SP
A1
+V
AC
AC
E
A2
AC
+V
AC
+V
A2
FROM
CUSTOMER'S
A.C. LINES
L1
L3
L2
A.C. MOTOR #1
A.C. MOTOR #2
SHIELD
0R
0R
JUMPER
A.C. MOTOR #2
A.C. MOTOR #1
111
S10
SEE
NOTE 1
SEE
NOTE 1
EARTH
GROUND
LOAD
LINE
+
-
A2
ISOLATED
AUTO MODE
SPEED
REFERENCE
+V
TO A2
T3
T2
T1
T3
T2
T1
T3
T2
T1
T1
T2
T3
T1
T2
T3
SEE
NOTE 2
SEE
NOTE 2
SEE
NOTE 2
SEE
NOTE 2
TO A2
TO A2
TO A2
SEE
NOTE 5
1T1
1T3
1T2
5T1
5T3
5T2
4T2
4T1
4T3
1T2
1T1
1T3
1T2
1T1
1T3
1T3
1T1
1T2
4T3
4T2
4T1
3T1
3T2
3T3
2T1
2T2
2T3
L2
L1
+2
+1
L3
A2
AC
AC
DRIVE
INPUT
FUSES
INPUT
RFI
FILTER
OPTION F
OPTION E
DC BUS
CHOKE
MANUAL
SPEED POT
OPTION S
2 MOTOR
"AND"
OPTION A
OPTION K
STD. AUTO MODE SPEED REFERENCE
STD.
4-20MADC
0-10VDC
MA
111
MA
3-15 PSI PRESSURE TRANSDUCER
OPTION P
5% LOAD
REACTOR
(SEE
TABLE 2)
OPTION N
L1
L2
L3
OPTION R
3% INPUT
REACTOR
TO DRIVE
TERMINAL
E
LEAD WIRE
OPTION N
GREEN
(GRN) (YEL)
(YEL)
(YEL)
DELTA-WYE
CAPACITIVE
INPUT FILTER
A5
GND LUG
OR
OPTION Z
OPTION X
(SEE
TABLE 3
FOR CB1
AMPERE
RATINGS)
PE
E
F10
F12
F11
A.C. MOTOR
(T1) (T3)
(T2)
(T1)
(T2)
(T3)
(T2)
(T1) (T3)
(T1) (T3)
(T2)
(T1) (T3)
(T2)
E
OFF
OFF
ON
ON
1
2
DIP SWITCH S1
TERMINAL
BOARD
DRIVE
FAULT
DRIVE
RUNNING
JUMPER
SERIAL
COMM. RUN
REMOVE JUMPER
FOR
DC BUS CHOKE
OPTIONS X OR Z
SEE THE
APPROPRIATE
TECHNICAL
MANUAL FOR
NETWORK
CONNECTIONS
OPTION L
CN2
CN1
CN2
CONTROL
BOARD
A6
TO CABINET
DOOR MOUNTED
DRIVE KEYPAD
WITHOUT
OPTION P
WITH OPTION P
WITH
OPTION S
RUN
FWD
BYPASS DRIVE
ENABLE
SEQ. COM.
FAULT RESET
HAND/AUTO
COM.
(R)
(S)
(T)
E7
DRIVE
(U)
(V)
(W)
+24V
MANUAL REF. IN
0-10VDC
(20K OHM)
+15VDC
20mA MAX.
ANALOG
COM.
ANALOG
COM.
(G) TB3
SHIELD
AUTO REF. IN
(AS SET
BY H3-08)
COM.
VCC
J2
3-14.5 PSI
PNEUMATIC
SIGNAL
3-15 PSI
FOLLOWER
PART NO.
UTC000038
4-20MA
OUTPUT
CB1
K1
F3
F4
F5
K2
L4
S10
K4
K5
K3
S12
S11
F9
F8
F7
EG
CG1
L2
PG1
L2/1.07
L11/1.23
L12/1.22
L3/1.14
L4/1.15
L5/1.16
L6/1.17
L7/1.18
L8/1.20
L9/1.21
L1/1.04
L1/1.04
L1
L13/1.24
A1
A4
L14/1.21
L15/1.20
L15/1.32
L14/1.31
2L1
2L2
2L3
1L3
1L3
1L1
1L2
111
1T1
1T2
1T3
MC
M4
M3
M2
MA
1L1
1L2
MA
MA
S1
S1
2T1
2T2
2T3
(W)
(B)
SN
S5
(R)
(R)
(B)
2 MOTOR
"OR"