Table 1.4 480v enclosure data, Physical installation 1 - 6 – Yaskawa E7B Drive Bypass User Manual
Page 18

Physical Installation 1 - 6
Table 1.4 480V Enclosure Data
Input
Volts
HP
1
Drive
Model
CIMR-
Bypass
2
Model
Number
NEC
FLA
OL
110%
1 min
Heat
3
Loss
Watts
Enclosure Dimensions
4
NEMA 1 & NEMA 12 -FVFF
H W D
inches
Weight
5
of
Assembly
Enclosure Dimensions w/Add-on
4
NEMA 1 & NEMA 12-FVFF
H W D
inches
Weight
5
of
Assembly
+Add-on
Box
Electrical
Schematic
480
0.5
42P21
E7B_B001
1.1
1.2
57
29.48 19.06 13.66
Dimension Drawing
6
S-5512
115 lbs
43.35 19.06 13.66
Dimension Drawing
S-5513
156 lbs
E7B-00
0.75
42P21
E7B_B001
1.6
1.8
57
1
42P21
E7B_B002
2.1
2.3
62
2
42P21
E7B_B003
3.4
3.7
89
3
42P21
E7B_B004
4.8
5.3
121
5
43P71
E7B_B007
7.6
8.4
155
7.5
45P51
E7B_B011
11.0
12.1
217
10
47P51
E7B_B014
14.0
15.4
318
127 lbs
164 lbs
15
49P01
E7B_B021
21.0
23.1
404
20
40111
E7B_B027
27.0
29.7
408
142 lbs
189 lbs
25
40151
E7B_B034
34.0
37.4
485
30
40181
E7B_B040
40.0
44.0
618
40
40241
E7B_B052
52.0
57.2
1040
40.48 25.63 14.66
Dimension Drawing
7
S-5514
203 lbs
55.35 25.63 14.66
Dimension Drawing
S-5515
281 lbs
50
40301
E7B_B065
65.0
71.5
1045
232 lbs
319 lbs
60
40371
E7B_B077
77.0
84.7
1197
75
40451
E7B_B096
96.0
105.6
1357
241 lbs
332 lbs
100
40551
E7B_B124
124.0
136.4
1749
125
40750
E7B_B156
156.0
171.6
2032
84.00 25.63 26.25
8
Dimension Drawing
9
S-5525
943 lbs
NOT REQUIRED
150
40900
E7B_B180
180.0
198.0
2486
200
41100
E7B_B240
240.0
264.0
2955
1240 lbs
250
41600
E7B_B302
302.0
332.2
4225
1352 lbs
300
41850
E7B_B361
361.0
397.1
4425
TBD
TBD
350
41850
E7B_B414
414.0
455.4
4451
400
42200
E7B_B477
477.0
524.7
5099
450
42200
E7B_B515
515.0
566.5
5154
500
43000
E7B_B590
590.0
649.0
7329
Note 1: Horsepower rating is based on a standard NEMA B 4-pole motor.
Note 2: The underscore position in these model numbers codes for the enclosure type: V = NEMA1, B = NEMA12 FVFF.
Note 3: Heat loss is the amount of heat dissipated by the drive at full load with all standard options available inside the enclosure. Drive heat sink losses are
included in the heat loss data. Heat loss data is for the enclosure without the add-on enclosure.
Note 4: Height dimension (H) excludes the mounting screw tabs. Depth dimension (D) excludes MCP disconnect handle.
Note 5: This data represents the total weight with all possible standard options. Weight could be less depending on the options specified.
Note 6: All standard options are available in this size enclosure except options E (RFI Filter) and K (5% Output Reactor). Options E and K require the
add-on enclosure.
Note 7: All options are available in this size enclosure except E (RFI Filter), R (3% Line Reactor), and K (5% Output Reactor). Only option E combined with
either option R or option K can be installed in the add-on enclosure. Options R and K together require an increase in the size of the E7 Bypass Enclosure.
Contact the factory if all three options are required. Options D (2 Motor “OR”) or A (2 Motor “AND”) for 75 Hp and 100 Hp, or for 200 Hp and 250 Hp,
require the next size enclosure.
Note 8: Heat sink mounted externally varies the depth dimension depending on the drive size. Depth will not exceed dimension shown.
Note 9: All options are available in this size enclosure except options D (2 Motor “OR”) or A (2 Motor “AND”) for 200 Hp and 250 Hp require the next
size enclosure.