480 vac, Table c.2 480vac drive and bypass specifications, Table c.2 480vac drive specifications (continued) – Yaskawa E7B Drive Bypass User Manual
Page 259: Specifications c - 3

Specifications C - 3
480 VAC
Table C.2 480VAC Drive and Bypass Specifications
Bypass Model Number E7B_ *
B001
B002
B003
B004
B007
B011
B014
B021
B027
B034
B040
Motor HP (460V)
0.5/0.75
1
1.5/2
3
5
7.5
10
15
20
25
30
Bypass rated output current (A)
1.6
2.1
3.4
4.8
7.6
11
14
21
27
34
40
Drive Model Number CIMR-E7U
42P2
42P2
42P2
42P2
43P7
45P5
47P5
49P01
4011
4015
4018
Drive rated output capacity (kVA)
1.4
1.6
2.8
4.0
5.8
9.5
13.0
16.0
21.0
26.0
30.0
Drive rated output current (A)
1.8
2.1
3.7
5.3
7.6
12.5
17.0
21.0
27.0
34.0
40.0
Drive max. output voltage (V)
3-phase; 380, 400, 415, 440, 460, or 480VAC (Proportional to input voltage.)
Drive max. output frequency (Hz)
120 Hz
Rated voltage (V)
Rated frequency (Hz)
3-phase, 380, 400, 415, 440, 460 or 480VAC, 50/60 Hz
Rated input current (A)
2.2
2.5
4.4
6.4
9.0
15
20
26
33
40
48
Allowable voltage fluctuation
+ 10%, - 15%
Allowable frequency fluctuation
±5%
Measures for
power supply
harmonics
DC Reactor
Optional
12-pulse
Rectification
Not possible
Table C.2 480VAC Drive Specifications (Continued)
Bypass Model Number E7B_ *
B052
B065
B077
B096
B124
B156
B180
B240
B302
–
–
–
Motor HP (460V)
40
50
60
75
100
125
150
200
250
300/
350
400/
450
500+
Bypass rated output current (A)
52
65
77
96
124
156
180
240
302
Drive Model Number CIMR-E7U
4024
4030
4037
4045
4055
4075
4090
4110
4160
4185
4220
4300
Drive rated output capacity (kVA)
40.0
51.0
59.0
73.0
95.0
120.0
140.0
180.0
230.0
315.0
390.0
510.0
Drive rated output current (A)
52.0
67.2
77.0
96.0
125.0
156.0
180.0
240.0
304.0
414.0
515.0
675.0
Drive max. output voltage (V)
3-phase, 380, 400, 415, 440, 460 or 480VAC (Proportional to input voltage)
Drive max. output frequency (Hz)
120 Hz
Max. voltage (V)
Rated frequency (Hz)
3-phase, 380, 400, 415, 440, 460, or 480VAC, 50/60 Hz
Rated input current (A)
57
74
85
106
134
172
198
264
334
456
567
743
Allowable voltage fluctuation
+ 10%, - 15%
Allowable frequency fluctuation
±5%
Measures for
power supply
harmonics
DC Reactor
Built-in
12-Pulse
Rectification
Possible
Note: The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor and Drive, be sure that the Bypass
and Drive's rated output current is equal to, or greater than, the motor's rated current.
A 3-wire phase-shifting transformer is required on the power supply for 12-pulse rectification.
Power s
uppl
y charac
te
ris
tic
s
Pow
er s
upply char
act
eri
sti
cs
C
ont
ro
l c
ha
rac
te
ri
stic
s
C
on
tr
ol
ch
ar
ac
te
ri
sti
cs