E. Conformance to European EMC Directive
In order to conform to EMC standards, the following methods are required for line filter application,
cable shielding and drive installation.
The line filter and Drive must be mounted on the same metal plate. The filter should be mounted as
close to the drive as practical. The cable must be kept as short as possible and the metal plate
should be securely grounded. The ground of the line filter and the drive must be bonded to the
metal plate with as much bare-metal contact as possible.
For main circuit input cables, a screened cable is recommended within the panel and is also
suggested for external connections. The screen of the cable should be connected to a solid ground.
For the motor cables, a screened cable (max. 20 m) must be used and the screen of the motor cable
should be connected to ground at both ends by a short connection, again using as much bare-metal
contact as practical.
For a more detailed explanation, refer to the manufacturer document EZZ006543, “Installation
Guidelines For EMC Directive using AC Drive Products.”
Table 1-4 and Figure 1-4 show the line filter list for EMC standards and the installation/wiring of the
Drive and line filter.
Model
Line Filter
CIMR-
Part Number
Rated
Weight
Dimensions in in. (mm)
Mounting Dim. in in. (mm)
Screw
V7*
MV
FIL00
Current (A)
lbs. (kg)
H x W x D
(1)
H1 x W1
Size
20P1
A001
20P2
A002
20P4
A003
1083
10
1.8 (0.8)
7.6 x 3.2 x 2.0 (194 x 82 x 50)
7.1 x 2.4 (181 x 62)
M5
20P7
A005
21P5
A008
1084
16
2.2 (1.0) 6.7 x 4.4 x 2.0 (169 x 111 x 50)
6.1 x 3.6 (156 x 91)
M5
22P2
A011
23P7
A017
1085
26
2.4 (1.1) 6.9 x 5.7 x 2.0 (174 x 144 x 50)
6.3 x 4.7 (161 x 120)
M5
25P5
A025
1100
50
5.1 (2.3) 12.0 x 7.2 x 2.2 (304 x 184 x 56) 11.3 x 5.9 (288 x 150)
M6
27P5
A033
40P2
B001
1086
5
2.2 (1.0) 6.7 x 4.4 x 1.8 (169 x 111 x 45)
6.1 x 3.6 (156 x 91)
M5
40P4
B002
40P7
B003
41P5
B005
1087
10
2.2 (1.0) 6.7 x 4.4 x 1.8 (169 x 111 x 45)
6.1 x 3.6 (156 x 91)
M5
42P2
–
43P7
B009
1088
15
2.4 (1.1) 6.9 x 5.7 x 2.0 (174 x 144 x 50) 6.3 x 4.7 (161 x 120)
M5
45P5
B015
47P5
—
1101
30
5.1 (2.3) 12.0 x 7.2 x 2.2 (304 x 184 x 56) 11.3 x 5.9 (288 x 150)
M6
(1)
D is the distance the filter will extend outward from the surface of the metal plate.
Continued
1.4 ELECTRICAL INSTALLATION
W1
W
H1
H
D
4-d