beautypg.com

A2-2, Table a2-1. standard specifications (continued) – Yaskawa V7 Drives User Manual

Page 130

background image

A2-2

SECTION B. All Drives (Continued)

Motor overload protection

Electronic thermal overload relay

Motor coasts to stop at approx. 250%

Instantaneous overcurrent

of drive current

Motor coasts to stop after 1 min. at 150% of

Overload

drive rated current (7)

Motor coasts to stop if DC bus voltage exceeds

Overvoltage

410VDC (230V), 820VDC (460V)

Motor coasts to stop when DC bus voltage is

Undervoltage

210VDC or less (230V), 400VDC or less (460V)

The following operations are selectable:

Momentary Power Loss

• Not provided (stops if power loss is 15 ms or longer)

• Automatic restart at recovery from 0.5 sec. power loss

• Automatic restart

Heatsink overheat

Protected by electronic circuit

Independently programmable during accel and

Stall prevention level

constant-speed running. Selectable during decel.

Ground fault

Protected by electronic circuit (overcurrent level)

ON until the DC bus voltage becomes 50V or less.

Power charge indication

RUN lamp says ON or digital operator LED stays ON.

(Charge LED is Provided for 400V)

Cooling Fan Fault

Protected by electronic circuit

Run/stop input

2-Wire or 3-Wire

Seven of the following input signals are selectable:

Forward/reverse run (3-Wire sequence), fault reset,

external fault (NO/NC contact input), multi-step speed operation,

Multi-function input

Jog command, accel/decel time select,

external baseblock (NO/NC contact input, speed search command,

accel/decel hold command, LOCAL/REMOTE selection,

communication/control circuit terminal selection,

emergency stop fault emergency stop alarm

Following output signals are selectable

(1 NO/NC contact output, 2 photo-coupler outputs):

Fault, running, zero speed, at frequency, frequency detection

Multi-function output

(output frequency

≤ or ≥ set value), during overtorque detection,

during undervoltage detection, minor error, during baseblock, operation mode,

inverter run ready, during fault retry, during UV, during speed search,

data output through communication

Analog monitor

0 to +10VDC output, programmable for output frequency or output current

Open Loop Vector Control, full-range automatic torque boost, auto restart,

Standard functions

upper/lower frequency limit, DC injection braking current/time at start/stop,

frequency reference gain/bias, prohibited frequencies,

analog meter calibrating gain, S-curve accel/decel, slip compensation,

MODBUS communications (RS485/422, Max. 19.2K bps),

frequency reference from digital operator pot

Status indicator LEDs

RUN and ALARM LEDs provided as standard

Digital Operator

Monitors frequency reference, output frequency,

output current, FWD/REF selection

Terminals

Screw terminals for both main circuit and control circuit

Wiring distance between

drive and motor

328 ft (100 m) or less

(3)

Enclosure

Open Type/NEMA type 1/NEMA type 4X/12

Cooling method

Self-cooling/cooling fan

Ambient temperature

14 to 104°F (-10 to 40°C)

Humidity

95% RH or less (non-condensing)

Storage temperature

(4)

-4 to 140°F (-20 to 60°C)

Location

Indoor (free from corrosive gases or dust)

Elevation

3,280 feet (1,000 m) or less

Vibration

Up to 1G, at less than 20 Hz;

up to 0.2G, at 20 to 50 Hz

Table A2-1. Standard Specifications (Continued)

Protectiv

e Functions

En

vironmental

conditions

Other Functions

Input signals

Output signals

Displa

y

NOTES:

(1)

Based on an N.E.C. standard 4-pole motor for max. applicable motor output.

(2)

Shows deceleration torque for an uncoupled motor decelerating from 60 Hz in 0.1 seconds.

(3)

Contact Yaskawa for wiring distances greater than 328 ft. (100 m).

(4)

Temperature during shipping (for short periods of time).

(5)

On NEMA type 4X/12 model only, maximum continuous rating of 30.8 A is 40 degrees C maximum ambient. For 33.0 A maximum
continuous rating, maximum ambient is 32 degrees C.

(6)

Applies to NEMA type 4X/12 model only.

(7)

On Model 47P5 NEMA type 4X/12 (21A), overload is 120% for 1 minute.