9.5 Failure Trace Read Function (FTRC-RD)
9-9
9.5 Failure Trace Read Function (FTRC-RD)
[Outline]
Reads the failure trace data and stores them in the user register. The data in the trace buffer can be
read out upon designating the number of records needed. Either the failure occurrence data or the
restoration data are designated for readout. Enables the reset (initialization) of the failure trace buffer.
[Format]
Symbol : FTRC-RD
Full Name : Failure-Trace Read
Category : SYSTEM
Icon :
[Parameter]
I/O
Definition
Parameter Name
I/O
Designation
Setting
Execute
B-VAL
Failure trace readout command
Reset
B-VAL
Failure trace buffer reset command
Type
I-REG
Type of data read
1 : Occurrence data
2 : Restoration data
Rec-Size
I-REG
Number of read records
Occurrence data : 1 to 64 Restoration data : 450
Input
Dat-Adr
Address input
Head register address for reading (address of MW or DW)
Complete
B-VAL
Completion of failure trace read
Error
B-VAL
Occurrence of error
Status
I-REG
Failure trace read execution status
Rec-Size
I-REG
Number of read records
Output
Rec-Len
I-REG
Length of read record
Table 9.3 Failure Trace Read Execution Status (STATUS)
Name Bit
No.
Remarks
System Reserved
Bit 0~Bit 7
No trace definition
Bit8
The function will not be executed.
Designated type No. error
Bit9
The function will not be executed.
System Reserved
Bit10
Error in the designated
number of records
Bit11
The function will not be executed.
Data storage error
Bit12
The function will not be executed.
System Reserved
Bit13
System Reserved
Bit14
Address input error
Bit15
The function will not be executed.