Cpu rack, Shield – Yaskawa YASNAC PC NC Connecting Manual User Manual
Page 51

3 - 6
YASNAC PCNC Connecting Manual
Chapter 3: Connection of PCNC Operation Panel
(e) Connection details Between PCNC CPU unit and Touch screen
(f) Connection detailed between PCNC CPU UNIT and SERVO ON/ SHUT DOWN
A T X M O T H E R B O A R D
D C D - 1
R X - 2
T X - 3
D T R - 4
G N D - 5
D S R - 6
R T S - 7
C T S - 8
R I - 9
S H E L L
C O M 1
P 2
- 1 D C D
- 3 R X D
- 5 T X D
- 7 D T R
- 9 G N D
- 2 D S R
- 4 R T S
- 6 C T S
- 8 R I
T O U C H S C R E E N
C O N T R O L L E R
H - 1
X - 2
S - 3
Y - 4
L - 5
P 3
T O U C H S C R E E N
F R O M T / S
C O N T R O L L E R
P O W E R
( 6 - 1 4 B )
- 1 + 5 V
- 2 G N D
- 1 0 k e y
P 4
- 1 D C D
- 2 R X
- 3 T X
- 4 D T R
- 5 G N D
- 6 D S R
- 7 R T S
- 8 C T S
- 9 R I
- 1 + 5 V
- 2 G N D
- 3
- 4
S H E L L
F E R R IT E
C O R E
F E R R I T E
C O R E
TOUCH SCREEN POWER
CABLE UWR00267
CPU RACK
AUX DC
OUTPUT
(5/12 VDC)
12V
MACHINE CONTROL CABINET
MACHINE OPERATION BOX
WIRE DUCT
GND
FLOPPY DISK DRIVE
POWER
POWER
MAIN DC
POWER
CABLE
UWR00264
FDD POWER
CABLE
UWR00266
TOUCH
SCREEN
POWER MID-
CABLE
UWR00298
JUMPER
JUMPER
5V
GND
TOUCH SCREEN
SERIAL
CONTROLLER
5V
GND
6P DOUBLE ROW COVERED TERMINAL STRIP
(SUCH AS BEAU # 18006-10A OR EQUIVALENT)
GND
5V
Shield
To be arranged by MTB
Terminal block