beautypg.com

Table 1.3.1.1: heat exchangers, Rex1550, 100w /10oc – Yaskawa YASNAC PC NC Connecting Manual User Manual

Page 26: 295 width x 890 height x 50 depth, Heatex02, 250w /10oc, 440 width x 924 height x 50 depth

background image

1 - 8

YASNAC PCNC Connecting ManualChapter 1: General

(2) Heat Exchanger Cooling Capacity

Where cooling capacity is insufficient even with a circulating fan mounted in the
enclosure, Yaskawa can provide heat exchangers.

The heat generation indicated in the above table is the allowable heat generated when the
internal temperature increase in the enclosure is limited to under 10

o

C.

Example: Allowable Heat Generated in the Enclosure with Heat Exchanger

The amount of internal heat generated to make the internal temperature under 10

o

C when

the enclosure is equipped with a HEATEX02 Heat Exchanger is expressed by the
following equation:

.....................................................

(3) Mounting Heat Exchanger

Heat exchanger should be mounted on the enclosure provided by the machine tool
builder. Fig. 1.5 shows a mounting example. Mount the exchanger so that the internal air
is drawn from the upper portion and discharged through the lower portion, while external
air is drawn in from the lower portion and discharged through the upper portion.

Fig 1.3.1.1: Mounting of Heat Exchanger on the enclosure made by Machine builder

Table 1.3.1.1: Heat Exchangers

Heat Exchanger

Cooling Capacity

External Dimensions (mm)

REX1550

100W /10

o

C

295 width x 890 height x 50 depth

HEATEX02

250W /10

o

C

440 width x 924 height x 50 depth

P= k

.

A

.

∆Τ+ 250

W

/10

o

C

= 6 x 4.16 x 10 + 250
= 499 W/

10

o

C

therefore, it is necessary to be under 499W.

Heat exchanger

Enclosure

External air

Internal air