5.2 Alarm Display Table
5-3
5
5.2 Alarm Display Table
The re-engineered SERVOPACK model CACR-SRBF has the same alarm function as that of
Σ-III series
SERVOPACK.
If an alarm occurs, the servomotor can be stopped by doing either of the following operations.
• DB stop: Stops the servomotor immediately using the dynamic brake.
• Zero-speed stop: Stops the servomotor by setting the speed reference to “0.”
Table 5.1 Alarm Display Table
Alarm
Display
Alarm Name
Meaning
Servomo-
tor Stop
Method
Alarm
Reset
Alarm Code Output
Servo
Alarm
(ALM)
Output
ALO1
ALO2
ALO3
A.020
Parameter Checksum
Error
The data of the parameter in the
SERVOPACK is incorrect.
DB stop
N/A
H
H
H
H
A.021
Parameter Format Error
The data of the parameter in the
SERVOPACK is incorrect.
DB stop
N/A
A.022
System Checksum Error
The data of the parameter in the
SERVOPACK is incorrect.
DB stop
N/A
A.023
Parameter Password Error The data of the parameter in the
SERVOPACK is incorrect.
DB stop
N/A
A.030
Main Circuit Detector
Error
Detection data for power circuit is
incorrect.
DB stop
Available
A.031
Main Circuit (Power
Pack) Alarm
The switch S2 is set incorrectly
DB stop
N/A
A.040
Parameter Setting Error
The parameter setting is outside the
allowable setting range.
DB stop
N/A
A.041
Dividing Pulse Output
Setting Error
The PG dividing pulse setting
(Pn212) is outside the allowable set-
ting range or not satisfies the setting
conditions.
This alarm may occur when using-
SRBF1E or -
SRBF1Y.
DB stop
N/A
A.042
Parameter Combination
Error
Combination of some parameters
exceeds the setting range.
DB stop
N/A
A.050
Combination Error
SERVOPACK and servomotor capac-
ities do not match each other.
DB stop
Available
A.051
Unsupported Product
Alarm
The serial converter unit unsup-
ported was connected.
DB stop
N/A
A.0b0
Servo ON reference
Invalid Alarm
The Host controller reference was
sent to turn the Servo ON after the
Servo ON function was used with the
Digital Operator or SigmaWin+.
DB stop
Available
A.100
Overcurrent or Heat Sink
Overheated
An overcurrent flowed through the
IGBT.
Heat sink of SERVOPACK was over-
heated.
DB stop
N/A
L
H
H
H
A.300
Regeneration Error
Detected
Regenerative circuit or regenerative
resistor is faulty.
DB stop
Available
L
L
H
H
A.320
Regenerative Overload
Regenerative energy exceeds regen-
erative resistor capacity.
Zero speed
stop
Available
A.330
Main Circuit Power
Supply Wiring Error
The power supply to the main circuit
does not match the parameter Pn001
setting.
DB stop
Available
A.400
Overvoltage
Main circuit DC voltage is exces-
sively high.
DB stop
Available
H
H
L
H
A.410
Undervoltage
Main circuit DC voltage is exces-
sively low.
Zero speed
stop
Available