4.2.2 List of Parameters
4-12
Pn501
Zero Clamp Level
0 to 10000 min
-1
1 min
-1
10 min
-1
Immediately
Cn-0F
Pn502
Zero Speed Level
1 to 10000 min
-1
1 min
-1
20 min
-1
Immediately
Cn-0B
Pn503
Speed Coincidence Signal Output
Width
0 to 100 min
-1
1 min
-1
10 min
-1
Immediately
−
Pn506
Brake Reference - Servo OFF
Delay Time
(0 to 50)
×
10 ms
10 ms
0 ms
Immediately
Cn-12
Pn507
Brake Reference Output Speed
Level
0 to 10000 min
-1
1 min
-1
100 min
-1
Immediately
Cn-15
Pn508
Waiting Time for Brake Signal
When Motor Running
(10 to 100)
×
10 ms
10 ms
500 ms
Immediately
Cn-16
Pn509
Instantaneous Power Cut Hold
Time
20 to 1000 ms
1 ms
20 ms
Immediately
−
Pn50A
Input Signal Selection 1
−
−
2100
After restart
−
Pn50B
Input Signal Selection 2
−
−
6543
After restart
−
Pn50C
Input Signal Selection 3
−
−
8888
After restart
−
Pn50D
Input Signal Selection 4
−
−
8888
After restart
−
Pn50E
Output Signal Selection 1
−
−
3211
After restart
−
Pn50F
Output Signal Selection 2
−
−
0
After restart
−
Pn510
Output Signal Selection 3
−
−
0
After restart
−
Pn512
Output Signal Reversal Setting
−
−
0
After restart
−
Pn520
Excessive Position Error Alarm
Level
1 to 1073741824 (2
30
)
reference units
1 reference
unit
262144
reference
units
Immediately
−
Pn522
Positioning Completed Width
0 to 1073741824 (2
30
)
reference units
1 reference
unit
7 reference
units
Immediately
−
(cont’d)
Parameter
No.
Name
Setting Range
Unit
Factory
Setting
Setting
Validation
Conventional
Model
SRBE/BY
Constant No.
Note: The parameters in shaded area have been set according to the SERVOPACK model before shipment.