Related parameters and functions, 2 electronic line shaft – Yaskawa A1000 User Manual
Page 8

2 Electronic Line Shaft
8
YASKAWA TM.A1000SW.064 Electronic Line Shaft with Alignment A1000 Custom Software Supplement
Related Parameters and Functions
lists terms and symbols used in this section to indicate which parameters are available in which control modes.
Table 1 Symbols and Icons Used in Parameter Descriptions
The parameters in the tables below are used to set up the drive for operation with the software.
Table 2 Modified Parameters
Symbol
Description
Parameter is available in all control modes.
Parameter is available when operating the drive with V/f Control.
Parameter is available when operating the drive with V/f with PG Control.
Parameter is available when operating the drive with Open Loop Vector.
Parameter is available when operating the drive with Closed Loop Vector.
Parameter is available when operating the drive with Open Loop Vector for PM motors.
Parameter is available when operating the drive with Advanced Open Loop Vector for PM motors.
Parameter is available when operating the drive with Closed Loop Vector for PM motors.
Parameter is NOT available when operating the drive in the control mode.
Parameter can be changed during run.
Motor 2
Refers to a second motor when the drive is operating two motors. Switch between these motors using the multi-function input
terminals.
No.
(Addr.
Hex)
Name
(Digital Operator Display)
Description
Values
F1-01
(380)
PG1 Pulses per Revolution
(PG Pulses/Rev)
Sets the number of pulses for a PG option card connected to port CN5-C.
Default: 1024 ppr
Min: 1
Max.: 60000
F1-02
(381)
Operation Selection at PG Open
Circuit (PGo)
(PG Fdbk Loss Sel)
Sets the operation when a PGo is detected on a PG option card connected to port
CN5-C.
0: Ramp to Stop
1: Coast to Stop
2: Fast Stop
3: Alarm Only
4: No Alarm Display
Default: 1
Range: 0 to 4
F1-05
(384)
PG 1 Rotation Selection
(PG1 Rotation Sel)
Sets the direction of forward travel for the PG card installed in CN5-C.
0: Pulse A Leads
1: Pulse B Leads
Default: 0
Range: 0, 1
F1-14
(38D)
PG Open-Circuit Detection Time
(PGO Detect Time)
Sets the amount of time required to trigger a PG Open fault (PGo).
Default: 2.0 s
Min: 0.0
Max.: 10.0
F1-21
(3BC)
PG 1 Signal Selection
(PG1 Signal Sel)
Selects single-channel/quadrature detection mode for the PG option card 1.
0: A Pulse Detection
1: AB Pulse Detection
Default: 1
Range: 0, 1
All Modes
V/f
V/f
V/f w PG
V/f w PG
OLV
OLV
OLV
OLV
CLV
CLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM
AOLV/PM
CLV/PM
OLV/PM
AOLV/PM
CLV/PM