8 object dictionary – Yaskawa 1000 Series Drive Option - CANopen Technical Manual User Manual
Page 23
8 Object Dictionary
YASKAWA ELECTRIC SIEP C730600 45B 1000-Series Option SI-S3 Technical Manual
23
■
2120 (Hex) / 2121 (Hex) - Output Current
These objects can be used to monitor the drive output current in amperes. The current value resolution is the same as in drive monitor U1-03 (For
details, refer to the Technical Manual for the drive). The value in object 2120 (Hex) is not filtered. For the value in object 2121 (Hex), a Change of
State filter can be set up as explained in
Change of State Filter on page 29
.
■
2130 (Hex) / 2131 (Hex) - Output Torque Reference
These objects can be used to monitor the output torque reference. The value in object 2130 (Hex) is not filtered. For the value in object 2131 (Hex),
a Change of State filter can be set up as explained in
Change of State Filter on page 29
The availability of this object content depends on the drive control mode. If the selected control mode does not support this monitor (equal to drive
monitor U1-09), the torque reference monitor value will be 0. Refer to the drive technical manual for details.
■
2140 (Hex) - MEMOBUS/Modbus Read Response
This object contains the data of the drive MEMOBUS/Modbus register specified in object 2040 (Hex). Bytes 1 and 2 of subindex 1 will contain the
data, and bytes 3 and 4 will contain the MEMOBUS/Modbus Address that was read.
■
2150 (Hex) - MEMOBUS/Modbus Write Response
This object contains the response from the drive when writing a drive parameter with a MEMOBUS/Modbus write command (object 2050 (Hex)).
Bytes 1 and 2 of subindex 1 will contain the data that was written, and bytes 3 and 4 will contain the MEMOBUS/Modbus Address that was written
to.
■
2155 (Hex) - PDO Parameter Write Response
Note: Available in option card software version 3102 and later.
This object contains the response from the drive when writing a drive parameter directly using a RxPDO. Byte 1 contains the lower byte and byte 2
contains the higher byte of the message identifier (COB-ID) for the message that contains the parameter write request. Byte 3 contains the number
of errors. This object can only be read if the SI-S3 option is in the Operational state.
Refer to
Accessing Drive Parameters, Monitors and Control Registers Using PDOs on page 31
for details on writing parameters using PDOs.
■
2160 (Hex) - MEMOBUS/Modbus Not Limited Enter Command Response
This object contains the response from the drive when writing an Enter command using object 2060 (Hex).
Index (Hex)
<1> Available in option card software version 3102 and later.
<2> Read / Write access when SI-S3 is in Pre-Operational state, Read only access if the SI-S3 is in the Operational state or if the drive is running.
Subindex
Content
Default
Access
PDO Mapping Data Length Update Cycle
2120
0
Output Current
-
Read Only
Possible
2 byte
8 ms
0
Number of entries
4
Read Only
No
1 byte
-
1
Output Current
-
Read Only
Possible
2 byte
8 ms
2
MEMOBUS/Modbus register address for content
00FB (Hex)
Read Only
No
2 byte
-
3
Filter value
FFFF (Hex)
Read / Write
No
2 byte
4
Value filter type
0 (Analog)
Read / Write
No
2 byte
Index (Hex)
<1> Available in option card software version 3102 and later.
<2> Read / Write access when SI-S3 is in Pre-Operational state, Read only access if the SI-S3 is in the Operational state or if the drive is running.
Subindex
Content
Default
Access
PDO Mapping Data Length Update Cycle
2130
0
Torque Reference
-
Read Only
Possible
2 byte
8 ms
0
Number of entries
4
Read Only
No
1 byte
-
1
Torque Reference
-
Read Only
Possible
2 byte
8 ms
2
MEMOBUS/Modbus register address for content
0048 (Hex)
Read Only
No
2 byte
-
3
Filter value
FFFF (Hex)
Read / Write
No
2 byte
4
Value filter type
0 (Analog)
Read / Write
No
2byte
Index (Hex)
Subindex
Content
Access
PDO Mapping
Data Length
2140
0
Number of entries
Read Only
Possible
1 byte
1
MEMOBUS/Modbus read response
2 + 2 byte
MEMOBUS/Modbus
Data + Address
Index (Hex)
Subindex
Content
Access
PDO Mapping
Data Length
2150
0
Number of entries
Read Only
Possible
1 byte
1
MEMOBUS/Modbus write response
2 + 2 byte
MEMOBUS/Modbus
Data + Address
Index (Hex)
Subindex
Content
Access
PDO Mapping
Data Length
2155
0
PDO Parameter Write Response (COB-ID of the
RxPDO and number of errors)
Read Only
Possible
3 byte
Index (Hex)
Subindex
Content
Access
PDO Mapping
Data Length
2160
0
MEMOBUS/Modbus not limited enter command
response
Read Only
Possible
4 byte