beautypg.com

SMA SB 3600SE-10 Service Manual User Manual

Page 19

background image

Error number

Display message, cause and corrective measures

6610

Self-diagnosis > Battery overvoltage
Corrective measures:

• Turn the DC load-break switch towards OFF until it snaps into place

at position O.

• Contact the SMA Service Line and clarify the next steps.

6701 to 6702

Comm. disturbed
An error has occurred in the internal communication of the inverter. The
inverter continues feeding power into the grid.
Corrective measures:

• If this message is displayed frequently, contact the

SMA Service Line.

6801 to 6802

Self diagnosis > Input A defective
Input A of the inverter is defective.
Corrective measures:

• Contact the SMA Service Line.

6901 to 6902

Self diagnosis > Input B defective
Input B of the inverter is defective.
Corrective measures:

• Contact the SMA Service Line.

7001 to 7002

Sensor fault
A temperature sensor in the inverter is defective and the inverter interrupts
the feed-in operation.
Corrective measures:

• Contact the SMA Service Line.

7008

Disturbance sensor display temperature
The ambient temperature sensor is defective. The display is not switched
off at temperatures below -25°C and, as a result, it may have been de-
stroyed. The inverter continues feeding power into the grid.
Corrective measures:

• Contact the SMA Service Line.

7102

Parameter file not found or defective
The parameter file was not found or is defective. The update failed. The
inverter continues feeding power into the grid.
Corrective measures:

• Copy the parameter file to the correct folder again.

4 Troubleshooting

SMA Solar Technology AG

Service Manual

19

SB36-50SE-SG-en-10