Error number

Display message, cause and corrective measures

3901 to 3902

Waiting for DC start conditions > Start conditions not met
The feed-in conditions for the utility grid are not yet fulfilled.
Corrective measures:

• Wait for higher irradiation.
• If this message is displayed frequently in the morning, increase the

voltage limit for starting grid feed-in. Change the parameter Critical
voltage to start feed-in
.

• If this message is displayed frequently with medium irradiation,

ensure that the PV array is correctly rated.

6001 to 6462

Self diagnosis > Interference of device
The cause must be determined by the SMA Service Line.
Corrective measures:

• Contact the SMA Service Line.

6501 to 6513

Self diagnosis > Overtemperature
The inverter has switched off due to excessive temperature.
Corrective measures:

• Clean the cooling fins on the rear of the enclosure and the air ducts

on the top using a soft brush.

• Ensure that the inverter has sufficient ventilation.

6603 to 6604

Self diagnosis > Overload
The inverter has detected an internal overload and interrupts the feed-in
operation.
Corrective measures:

• Contact the SMA Service Line.

6607 to 6608

Self-diagnosis > Battery overcurrent
Internal error. The inverter continues to feed into the utility grid.
Corrective measures:

• If this message is displayed frequently, contact the

SMA Service Line.

6609

Self-diagnosis > Battery undervoltage
Internal error. The inverter continues to feed into the utility grid.
Corrective measures:

• If this message is displayed frequently, contact the

SMA Service Line.