4 troubleshooting, 1 led signals, 2 event messages – SMA SB 3600SE-10 Service Manual User Manual
Page 12: Troubleshooting, Led signals, Event messages
4 Troubleshooting
4.1 LED Signals
The LEDs indicate the operating state of the inverter.
LED
Status
Explanation
Green LED
glowing
Operation
flashing
The requirements for the connection to the utility
grid have not been met.
Red LED
glowing
Error
The red LED indicates an error (see Section 4.3
"Error Messages", page 13).
Blue LED
-
No function
4.2 Event Messages
Display message
Cause
Set parameter
The parameter change is adopted.
Parameters set success-
fully
The parameter changes were successfully adopted.
Update file OK
The update file found is valid.
Memory card is read
USB stick (memory card) is searched for the update file and the update
file is checked.
No new update on the
memory card
On the USB stick (memory card), there is an update file that has already
been used.
Update communication The inverter is updating the communication component.
Update main CPU
The inverter is updating the inverter component.
Update completed
The inverter has successfully completed the update.
Condition test success-
ful
Conditions from the update file have been tested successfully.
Update transport
started
Update file is being copied.
Update transport suc-
cessful
Update file was copied successfully to the inverter's internal memory.
Update BMS
Battery management software (BMS) is updated.
Grid parameter un-
changed
The parameters have been locked and cannot be changed.