beautypg.com

Comparison: differences in mdi operation – HEIDENHAIN TNC 620 (73498x-02) User Manual

Page 593

background image

Functions of the TNC 620 and the iTNC 530 compared 18.5

18

TNC 620 | User's Manual
HEIDENHAIN Conversational Programming | 5/2013

593

Function

TNC 620

iTNC 530

PLANE function

:

TABLE ROT/COORD ROT not
defined

Configured setting is used

COORD ROT is used

Machine is configured for axis
angle

All

PLANE functions can be

used

Only

PLANE AXIAL is executed

Programming an incremental
spatial angle according to
PLANE AXIAL

Error message is issued

Incremental spatial angle is
interpreted as an absolute
value

Programming an incremental
axis angle according to

PLANE

SPATIAL if the machine is
configured for spatial angle

Error message is issued

Incremental axis angle is
interpreted as an absolute
value

Special functions for cycle
programming:

FN17

Function available, details are
different

Function available, details are
different

FN18

Function available, details are
different

Function available, details are
different

Compensation of tool length in
the position display

The

DL value from the TOOL

CALL and the tool length entries

L and DL from the tool table are
taken into account in the position
display

The tool length entries

L and DL

from the tool table are taken into
account in the position display

Comparison: Differences in MDI operation

Function

TNC 620

iTNC 530

Execution of connected
sequences

Function partially available

Function available

Saving modally effective functions

Function partially available

Function available