beautypg.com

Setting the datum in a tilted coordinate system – HEIDENHAIN TNC 620 (73498x-02) User Manual

Page 488

background image

Manual operation and setup

14.10 Tilting the working plane (software option 1)

14

488

TNC 620 | User's Manual

HEIDENHAIN Conversational Programming | 5/2013

Setting the datum in a tilted coordinate system

After you have positioned the rotary axes, set the datum in the
same manner as for a non-tilted system. The behavior of the TNC
during datum setting depends on the setting in machine parameter
CfgPresetSettings/chkTiltingAxes:

chkTiltingAxes: On

With an active tilted working plane, the

TNC checks during datum setting in the X, Y and Z axes whether
the current coordinates of the rotary axes agree with the tilt
angles that you defined (3-D ROT menu). If the tilted working
plane function is not active, the TNC checks whether the rotary
axes are at 0° (actual positions). If the positions do not agree,
the TNC will display an error message.

chkTiltingAxes: Off

The TNC does not check whether the

current coordinates of the rotary axes (actual positions) agree
with the tilt angles that you defined.

Danger of collision!

Always set a reference point in all three reference
axes.