Machine-specific user parameters 18.1 – HEIDENHAIN TNC 620 (73498x-02) User Manual
Page 549

Machine-specific user parameters 18.1
18
TNC 620 | User's Manual
HEIDENHAIN Conversational Programming | 5/2013
549
Parameter settings
DisplaySettings
Behavior with control start-up
Acknowledge "Power interruption" message
TRUE: Control start-up is only continued after message acknowledgement
FALSE: "Power interruption" message not displayed
Display of cycles
TNC_STD: Display cycles with comment texts
TNC_PARAM: Display cycles without comment texts
DisplaySettings
Settings for program-run graphics
Type of graphic display
High (compute-intensive): The position of linear and rotary axes is considered in the
program-run graphics (3D)
Low: Only the position of linear axes is considered in the program-run graphics (2.5D)
Disabled: Program-run graphics deactivated
ProbeSettings
Configuration of probing behavior
Manual operation: Basic rotation considered
TRUE: Consider active basic rotation with probing
FALSE: Always traverse paraxially during probing
Automatic mode: Multiple measuring with probing functions
1 to 3: Number of probes for each probing routine
Automatic mode: Confidence range for multiple measuring
0.002 to 0.999 [mm]: Range in which the measured value must lie with multiple
measuring
Configuration of a round stylus
Coordinates of stylus center point
[0]: X coordinate of the stylus center point with reference to the machine datum
[1]: Y coordinate of the stylus center point with reference to the machine datum
[2]: Z coordinate of the stylus center point with reference to the machine datum
Setup clearance over the stylus for pre-positioning
0.001 to 99 999.9999 [mm]: Setup clearance in the tool axis direction
Clearance zone around the stylus for pre-positioning
0.001 to 99 999.9999 [mm]: Setup clearance in the plane vertically to the tool axis