D19 plc: transfer values to the plc, 7 a d ditional f unctions – HEIDENHAIN TNC 620 (340 56x-02) ISO programming User Manual
Page 221

HEIDENHAIN TNC 620
221
8.7 A
d
ditional F
unctions
D19 PLC: Transfer values to the PLC
The function D19 transfers up to two numerical values or Q parameters
to the PLC.
Increments and units: 0.1 µm or 0.0001°
Example: Transfer the numerical value 10 (which means 1 µm or
0.001°) to the PLC
17
-
TT: Wear tolerance in radius RTOL
18
-
TT: Direction of rotation DIRECT
0 = positive, –1 = negative
19
-
TT: Offset in plane R-OFFS
20
-
TT: Offset in length L-OFFS
21
-
TT: Break tolerance for length LBREAK
22
-
TT: Break tolerance in radius RBREAK
23
-
PLC value
24
-
Tool type TYPE
0 = milling cutter, 21 = touch probe
27
-
Corresponding row in the touch-probe table
32
-
Point angle
34
-
Lift off
Touch probe cycles, 990
1
-
Approach behavior:
0 = standard behavior
1 = effective radius, set-up clearance is zero
2
-
0 = probe monitoring off
1 = probe monitoring on
Execution status, 992
10
-
Block scan active
1 = yes, 0 = no
11
-
Search phase
14
-
Number of the last FN14 error
16
-
Real execution active
1 = execution , 2 = simulation
Group name, ID number
Number
Index
Meaning
N56 D19 P01 +10 P02 +Q3 *