Saving the basic rotation in the preset table, Displaying a basic rotation, Canceling a basic rotation – HEIDENHAIN iTNC 530 (340 49x-05) ISO programming User Manual
Page 460

460
Manual Operation and Setup
14.7 Compensating W
o
rk
piece Misalignment with a 3-D T
o
uc
h Pr
obe
Saving the basic rotation in the preset table
U
After the probing process, enter the preset number in which the
TNC is to save the active basic rotation in the Number in table:
input box
U
Press the ENTRY IN PRESET TABLE soft key to save the basic
rotation in the preset table
Saving the basic rotation in the pallet preset
table
U
After the probing process, enter the preset number in which the
TNC is to save the active basic rotation in the Number in table:
input box
U
Press the ENTRY IN PALLET PRES. TAB. soft key to save the basic
rotation in the preset table
The TNC shows an active pallet preset in the additional status display
(see “General pallet information (PAL tab)” on page 80).
Displaying a basic rotation
The angle of the basic rotation appears after ROTATION ANGLE
whenever PROBING ROT is selected. The TNC also displays the
rotation angle in the additional status display (STATUS POS.)
In the status display a symbol is shown for a basic rotation whenever
the TNC is moving the axes according to a basic rotation.
Canceling a basic rotation
U
Select the probe function by pressing the PROBING ROT soft key
U
Enter a rotation angle of zero and confirm with the ENT key
U
Terminate the probe function by pressing the END key
In order to store a basic rotation in the pallet preset table,
you must activate a zero preset before probing. A zero
preset consists of the entry 0 in all axes of the preset