beautypg.com

HEIDENHAIN iTNC 530 (340 49x-05) ISO programming User Manual

Page 354

background image

354

Programming: Special Functions

1

1

.5 A

d

aptiv

e

F

e

ed Contr

o

l Sof

tw

a

re

Option (AFC)

Proceed as follows to create the AFC.TAB file (only necessary if the
file does not yet exist):

U

Select the Programming and Editing operating mode

U

Press the PGM MGT soft key to call the file manager

U

Select the TNC:\ directory

U

Make the new file AFC.TAB and confirm with the ENT key: The TNC
shows a list of table formats

U

Select the AFC.TAB table format and confirm with the ENT key: The
TNC creates a table with the Standard control settings

SENS

Sensitivity (aggressiveness) of regulation. A value
between 50 and 200 can be entered. 50 is for slow
control, 200 for a very aggressive control. An aggressive
control reacts quickly and with strong changes to the
values, but it tends to overshoot. Recommended value:
100

PLC

Value that the TNC is to transfer to the PLC at the
beginning of a machining step. The machine tool builder
defines the function, so refer to your machine manual.

In the AFC.TAB table you can define as many control
settings (lines) as desired.

If there is no AFC.TAB table in the TNC:\ directory, the TNC
uses permanently defined internal control settings for the
teach-in cut. It is best, however, to work with the AFC.TAB
table.

Column