Sorting and Tolerance Checking

In the sorting and tolerance checking mode, the display unit
compares the displayed value with the programmed upper and
lower sorting limits. The sorting and tolerance checking mode is
enabled and disabled with operating parameter

P17.

Entering sorting limits

Sorting limits are entered in operating parameters

P18 and P19

(see “Operating Parameters”).

Sorting signals

The display indicators and switching outputs at D-sub
connection EXT (X41, see applicable section) sort the display
value into one of three classes.

Display

Meaning

=

Measured value is within sorting limits

<

Measured value is smaller than lower sorting limit

>

Measured value is greater than upper sorting limit

Operating parameters for sorting and tolerance checking

P17 CLASS

Sorting ON/OFF

P18 L.CLASS.

Lower sorting limit

P19 U.CLASS.

Lower sorting limit

Sorting

and

Tolerance

C

hecking

Example: Upper sorting limit = 26.02 mm
Lower sorting limit = 26.00 mm

Reject

Accept

Rework