Output Format of the Compensation-Value Table

A separate compensation-value table is prepared and transmitted for each axis to be corrected.

Line: Start

Each compensation-value output begins with the start character < * > ( HEX: 0x2A)

*

3 characters

Line: Counter model designation

Output of model designation and unit of measure

N D - 2 3 1 B M M

13 characters 5 characters 2 characters
Model display unit, left-aligned Unit of meas. End of line

Line: Axis to be corrected

Output of axis to be corrected

A X I S X 1 = 0

13 characters 3 char. 6 characters 2 characters
Axis to be corrected Separator Axis value End of line
left-aligned

block right-aligned

Line: Axis to be corrected

Output of axis to be corrected

X 1 F C T . X 1 = 0

13 characters 3 char. 6 characters 2 characters
Axis causing the error Separator Axis value End of line
left-aligned block right-aligned