Specifications
Specifications
Housing
ND 231 B
Benchtop design,
cast-metal housing (W · H · D)
239 mm · 84.6 mm · 224 mm
Operating temperature
0° to 45° C (32° to 113° F)
Storage temperature
–20 °C to 70 °C (–4 °F to 158 °F)
Weight
Approx. 1.5 kg (3.3 lb)
Relative humidity
< 75% annual average
< 90% in rare cases
Power supply
Primary-clocked power supply
100 Vac to 240 Vac
(–15% to +10%)
50 Hz to 60 Hz (± 2 Hz)
Line fuse
F 1 A inside the housing
Power consumption
8 W (typically)
Electromagnetic
compatibility
Class B according to EN 55022
Noise immunity
As per VDE 0843 Parts 2 and 4,
severity 4
Protection
IP40 according to IEC 529
Encoder inputs
For encoders with sinusoidal output
signals (11 µA
PP
);
Reference mark evaluation for distance-
coded and single reference marks
Input frequency
X1 and X2:
Max. 100 kHz for 30 m cable length
Display step
Adjustable
Datum points
Two
Functions
• Sorting and tolerance checking
• Switching and sorting signals
• Set display and reset display to
zero with external signal
• Measured value output
RS-232-C/V.24
Baud rates:
interface
110, 150, 300, 600, 1200, 2400,
4800, 9600, 19 200, 38 400 baud