HEIDENHAIN ND 231 B v.2 User Manual

Page 39

background image

39

Operating parameters for measured value output

Parameter

Function

P50 RS232

Baud rate

P51 RS232

Number of additional blank lines for
measured value output

Display freeze during measured value output

In operating parameter P23, you can specify how the
measured value output signal will affect the display unit.

Display freeze during measured value output

P23

Concurrent display, no display freeze: The
display value is the current measured value

DISPL. ACTL.

Frozen display: Display is stopped
(frozen) and updated by every
measured value output signal

DISPL. HOLD

Frozen/concurrent display: Display is
frozen as long as a measured value output
signal is present

DISPL. STOP

RS-232-C/V.24 Data Interface (X31)

187 + (11 • number of blank lines)

Measured value output via PRINT function

ä Press the MOD key (note parameter setting P86).

Duration of measured value transfer

t

D

=

[ s]

baud rate