List of operating parameters – HEIDENHAIN ND 231 B v.2 User Manual
Page 20
20
Parameter
Settings / Function
Parameter
Settings / Function
P42.1 to
P42.2
Backlash compensation
Input range (mm):
+9.999 to -9.999
Default setting:
0.000
= no backlash compensation
During a change in direction, the mechanical play between the
encoder and table, the so-called backlash, can cause error.
Positive backlash: The rotary encoder moves before the table,
therefore the display value is too high (positive value input).
Negative backlash: The rotary encoder moves after the table,
therefore the display value is too low (negative value input).
P43.1 REF
Reference marks X1
One reference mark
SINGLE REF.
Distance-coded with 500 • SP
(SP: signal period)
500 SP
Distance-coded with 1000 • SP
(e.g. for HEIDENHAIN LS ...C)
1000 SP
Distance-coded with 2000 • SP
2000 SP
Distance-coded with 5000 • SP
5000 SP
List of Operating Parameters
P43.2 REF
Reference marks X2
One reference mark
SINGLE REF.
Distance-coded with 500 • SP
(SP: signal period)
500 SP
Distance-coded with 1000 • SP
(e.g. for HEIDENHAIN LS ...C)
1000 SP
Distance-coded with 2000 • SP
2000 SP
Distance-coded with 5000 • SP
5000 SP
P44.1 REF
Reference mark evaluation
Evaluate the reference mark
REF. X1 ON
Do not evaluate the reference
mark
REF. X2 OFF
P44.2 REF
Reference mark evaluation
1)
Evaluate the reference mark
REF. X2 ON
Do not evaluate the reference
mark
REF. X2 OFF
P45.1 ALARM
Encoder monitoring X1
No monitoring
ALARM OFF
Monitor the frequency
FREQUENCY
Monitor contamination
CONTAMINAT.
Contamination + frequency FRQ. + CONT.
1)
If an encoder input is not assigned, it must be deactivated.
The settings go into effect after switch-on.