Parameter

Settings / Function

Parameter

Settings / Function

P42.1 to

P42.2

Backlash compensation
Input range (mm):

+9.999 to -9.999

Default setting:

0.000

= no backlash compensation

During a change in direction, the mechanical play between the
encoder and table, the so-called backlash, can cause error.
Positive backlash: The rotary encoder moves before the table,
therefore the display value is too high (positive value input).
Negative backlash: The rotary encoder moves after the table,
therefore the display value is too low (negative value input).

P43.1 REF

Reference marks X1
One reference mark

SINGLE REF.

Distance-coded with 500 • SP
(SP: signal period)

500 SP

Distance-coded with 1000 • SP
(e.g. for HEIDENHAIN LS ...C)

1000 SP

Distance-coded with 2000 • SP

2000 SP

Distance-coded with 5000 • SP

5000 SP

List of Operating Parameters

P43.2 REF

Reference marks X2
One reference mark

SINGLE REF.

Distance-coded with 500 • SP
(SP: signal period)

500 SP

Distance-coded with 1000 • SP
(e.g. for HEIDENHAIN LS ...C)

1000 SP

Distance-coded with 2000 • SP

2000 SP

Distance-coded with 5000 • SP

5000 SP

P44.1 REF

Reference mark evaluation
Evaluate the reference mark

REF. X1 ON

Do not evaluate the reference
mark

REF. X2 OFF

P44.2 REF

Reference mark evaluation

1)

Evaluate the reference mark

REF. X2 ON

Do not evaluate the reference
mark

REF. X2 OFF

P45.1 ALARM

Encoder monitoring X1
No monitoring

ALARM OFF

Monitor the frequency

FREQUENCY

Monitor contamination

CONTAMINAT.

Contamination + frequency FRQ. + CONT.

1)

If an encoder input is not assigned, it must be deactivated.
The settings go into effect after switch-on.