Output Format of the Compensation-Value Table

Compensation-value table for ND 231 B (axis X2): Active compensation

Compensation-value table

Description:

*

Start character ( * );

ND-231 B

MM

Model of display unit; unit of measure (MM or IN);

AXIS X2

= 1

Axis to be corrected, X1 = 0; X2 = 1;

X2 FCT. X2

= 1

Axis causing the error, X1 = 0; X2 = 1;

SPACING X2

= 15

Spacing X2 = 15 (range : 6 – 20)

DATUM X2

=

+ 15.2250

Datum X2: +15.2250 mm (value input)

CMP. NR. 00 =

+ 0.0000

Compensation value 0 = 0.0000 mm (compensation value 0 is always 0)

CMP. NR. 01 =

- 0.0300

Compensation values 1 – 10 are assigned values (value input)

CMP. NR. 02 =

- 0.0420

The axis is compensated from 15.2250 mm to 342.9050 mm.

CMP. NR. 03 =

- 0.0080

CMP. NR. 04 =

+ 0.0000

CMP. NR. 05 =

+ 0.0090

CMP. NR. 06 =

+ 0.0180

CMP. NR. 07 =

+ 0.0250

CMP. NR. 08 =

+ 0.0420

CMP. NR. 09 =

+ 0.0510

CMP. NR. 10 =

+ 0.0620

CMP. NR. 11 =

----------

Compensation values 11 – 63: no value entered (memory empty)

CMP. NR. 12 =

----------

CMP. NR. 13 =

----------

.

.

.

.

CMP. NR. 60

=

----------

CMP. NR. 61

=

----------

CMP. NR. 62

=

----------

CMP. NR. 63

=

----------

*

Final character (*);