GUIDE TO INSTALLATION AND OPERATION
SME-1901 / 1911 | 33
The upgrade file used here is contained in the zip file obtained from Grass Valley. Before beginning the procedure
below, open the zip file and extract the file named:
firmware-X.Y.Z.B.zip
where X.Y.Z is the package version and B is the build number. This file is the upgrade package used in the procedure
below.
1. The Densité frame containing the SME-1901/SME-1911 card to upgrade must not be Online in the iControl
Densite Manager. If it is in the list, set it to Standby for the duration of the upgrade procedure.
2. Click Miranda Interface Updater in the Tools menu of iControl Navigator v4 or iControl Solo v4 or execute the
stand-alone version.
Enter the Densité frame’s IP address in the Densite IP
address box and click Connect.
Click Open and choose the upgrade package. The Upgrade
Version displayed will only display the X in the X.Y.Z version
number.
The SME-1901/SME-1911 cards in the frame will no longer
be grayed. It is now possible to select the cards to upgrade
using the checkboxes in the Select column.
3. Click Upgrade. A message box will appear with a cautionary statement. Click Yes to continue.
The process will take approximately two hours for each card. While the upgrade is in progress, the card icon is
Yellow.
When the upgrade has been completed for a card, the message “Upgrade Successful” on a green background
will be displayed in the Status column.
4. Close the Miranda Interface Updater window by clicking the
icon in the upper right corner.