Environmental Criteria
Table A-15 lists the environmental criteria for the Profile Video File Server and the
PAC208/216.
Table A-14. Profile Video File Server Power Supply Specifications (from Manufacturer)
Characteristics
Description
Output voltages
Supplemental Data:+5Vdc @ 70 A max.
-5Vdc @ 5 A max.
+12Vdc
1
@ 10 A max.
+12Vdc
2
@ 6 A max.
-12Vdc @ 6A max.
Total wattage
Supplemental Data:1000 W maximum
Ripple
Supplemental Data:200 mV p-p on
+
5V supply
50 mV p-p on -5V supply
120 mV p-p on
+
12V supplies
225 mV p-p on -12V supply
Regulation
Supplemental Data:
±
3% on +5, -5, and -12 V supplies
±
5% on +12 V supplies
Table A-15. Environmental Criteria
Characteristics
Description
Operating Temperature
Requirement:
5
°
to 40
°
C (+41
°
to 122
°
F)
Storage Temperature
Requirement:
-40
°
to 65
°
C (-40
°
to 149
°
F)
Operating Altitude
Requirement:
To 15,000 feet (4572 meters)
Supplemental Data:IEC 950 compliant to 2000 meters
Storage Altitude
Requirement:
To 50,000 feet (15,240 meters)
Mechanical Shock
Mil Specification: Mil-T-28800D, Class 6 (Non-Operating Only)
Transportation
Requirement:
Qualified under NSTA Test Procedure 1A, Category II (24 inch drop)
Equipment Type
Supplemental Data:Information Technology
Equipment Class
Supplemental Data:Class I
Installation Category
Requirement:
Category II Local level, appliances, portable equipment, etc.
Pollution Degree
Requirement:
Level 2 Normally only non-conductive pollution occurs. Occasionally a
temporary conductivity caused by condensation must be expected.
Humidity
Requirement:
Operating 20% - 80%
Non-Operating 8% - 90%
Transportation 5% - 95%
Maximum Wet Bulb Temperature 26
°
Supplemental Data:Do not operate with visible moisture on the circuit boards