beautypg.com

A-10, Appendix a – Grass Valley PDR 200 Installation User Manual

Page 92

background image

Appendix A

A-8

Profile Video File Server Installation

Table A-8. Program Input Genlock

Characteristics

Description

Burst Frequency Lock Range

Requirement:

±

50 Hz at subcarrier

Supplemental Data:Remains locked or initial lock

Signal Amplitude Lock
Range

Requirement:

Stays locked to +6 dB and -3 dB

Phase Jitter (Analog Input and
Analog Output)

Requirement:

1

°

Phase Jitter (Analog Output
Only)

Requirement:

0.5

°

Hum Rejection

Requirement:

32 dB

Recovery Time

Requirement:

Fast - Within 35.7 mV in 2 to 3 lines
Medium - Within 35.7 mV in 10 to 30 lines
Slow - Within 35.7 mV in > 30 lines

Switch Points

Requirement:

Fast - Medium 30 to 40 dB signal-to-noise

Supplemental Data:Medium - Slow 20 to 30 dB signal-to-noise

Table A-9. Reference Genlock

Characteristics

Description

Color Field Detection, Based on
SCH Phase

Requirement:

Correct color framing for signals having an
average SCH phase

±

40

°

; Lockup

±

10

°

Supplemental Data:Once locked to color field, it will stay locked

over a range of 0

°

to

±

90

°

Burst Frequency Lock Range

Requirement:

PAL,

±

10 Hz at subcarrier

NTSC,

±

20 Hz at subcarrier

Signal Amplitude Lock Range

Requirement:

Stays locked to +6 dB and -3 dB

Reference Genlock Input Return
Loss

Requirement:

40 dB to 5 MHz

Table A-10. Time Code

Characteristics

Description

Input

Supplemental Data:Longitudinal Time Code. AC coupled, differential

input

Input Impedance

Supplemental Data:20 k

. Switch selectable 600

input.

Input Amplitude

Supplemental Data:0.1 V p-p, differential, minimum

Maximum Input Voltage

Supplemental Data:2.5 V p-p, differential, maximum