Setting the Reference Genlock

Profile Family

21

Setting the Reference Genlock

The Reference Genlock dialog box sets the genlock parameters. To open this
dialog box, click or double-click Genlock from the configuration tree and the
Reference Genlock dialog box appears.

Figure 12. Reference Genlock dialog box

Status Indicators

At the top of the dialog box, the status indicators display the current status of
the Genlock input: Locked to External Reference, Internal Clock Locked and
VITC Present. A green light indicates that the particular status is on. These
indicators cannot be edited.

VITC Reader Setting

If you use Automatic VITC detect, the Profile unit uses the range set in the
From and To lines to look for the VITC signals. If Automatic VITC detect is
not used, the unit expects to find the VITC signals on the VITC Reader Line 1
(default 10) or Line 2 (default 12).