Setting the timeout value, Misc. topics – Grass Valley NV9608 v.1.0 User Manual
Page 75

NV9616 Control Panel • User’s Guide
65
7. Misc. Topics
Setting the Timeout Value
Setting the Timeout Value
The NV9616 has panel options that use a timeout value. You can set the timeout value in NV9000-
SE Utilities. Choose the ‘SysParams’ table from the ‘Tables’ folder under the ‘Views’ navigation
pane. Click ‘Add’ and enter a timeout value as shown:
Figure 7-1. SysParams Table (in NV9000-SE Utilities)
The name of the parameter must be exactly as you see it here. The timeout value (expressed in sec-
onds) must be a non-negative value. A suggested value is 120 seconds (two minutes) or more. The
default timeout value is 30 seconds.
S
The timeout value applies to all panels in your NV9000’s panel and router network.
S
If you do not add a timeout value to the ‘SysParams’ table, the timeout period will be the
default of 30 seconds.