Setting the Timeout Value

Setting the Timeout Value

The NV9616 has panel options that use a timeout value. You can set the timeout value in NV9000-
SE Utilities. Choose the ‘SysParams’ table from the ‘Tables’ folder under the ‘Views’ navigation
pane. Click ‘Add’ and enter a timeout value as shown:

Figure 7-1. SysParams Table (in NV9000-SE Utilities)

The name of the parameter must be exactly as you see it here. The timeout value (expressed in sec-
onds) must be a non-negative value. A suggested value is 120 seconds (two minutes) or more. The
default timeout value is 30 seconds.

S

The timeout value applies to all panels in your NV9000’s panel and router network.

S

If you do not add a timeout value to the ‘SysParams’ table, the timeout period will be the
default of 30 seconds.