NV9616 Control Panel • User’s Guide

23

4. Configuration

Panel Options

• Lock page after timeout.

If you check this box, the panel will lock the current MD destination page after the panel is idle
for the timeout period.
To clear the lock, operators can press any enabled function button.
See

Setting the Timeout Value

on page 65.

• Clear preset when going from low tally to high tally.

If you check this box, the panel lets the operator clear a preset (in MD mode only) by deselect-
ing and reselecting a destination. When you deselect the destination, it goes low-tally, and when
you reselect it, it goes high-tally.
This method does the same thing a ‘Clear’ button does, but it does not require a ‘Clear’ button.
This might be advantageous if you want some other button in place of a ‘Clear’ button.

• Use continuous scrolling.

If you check this box, the panel scrolls MD destinations continuously. That is, the MD destina-
tion pages wrap around at the beginning and at the end of the page list.
The LCD buttons will show the first page in the list following the last when you are scrolling
down, and will show the last page following the first if you are scrolling up.
If you uncheck this box, the panel will stop scrolling when it reaches either the beginning or
end of the page list.
This option does not affect scrolling of salvos when the panel is in salvo mode or levels when
the panel is in X-Y mode.