Checkbox options, Configuration – Grass Valley NV9608 v.1.0 User Manual
Page 31

NV9616 Control Panel • User’s Guide
21
4. Configuration
Panel Options
Checkbox Options
The checkbox options section is at the bottom of the panel options section:
A check in the box enables the option. Clearing the checkbox disables the option.
By default, all the check box options are clear except ‘Use Continous Scrolling’.
XY Data
Routing Mode
Automatic
If a machine control (data) level is involved in the route, make the
route on the control level even if the control port is in use on the
source or destination device.
Semi-automatic
(recommended)
If the machine control port is in use on the source or destination
device, take all levels except control and allow the user to perform
the control level route by pressing ‘Take’ a second time. If ‘Take’ is
not pressed again, the route is cancelled.
If the control port is not in use, the control level take occurs
automatically.
Manual
A take on the data level must be performed manually as a breakaway
on the control level. The control level will never switch as part of a
multi-level take.
MD Data
Routing Mode
Automatic
If a data level is involved in the multi-destination route, connect the
source to the destinations, regardless of who is currently using the
devices. (Recommended.)
Manual
All multi-destination takes on the data level must be performed
manually as breakaways. The data level will never switch as part of a
multi-level take.
Default Name Set System Name
A list of “name sets” appears in the drop-down menu. The name sets
can be defined under the System Management pane of NV9000-SE
Utilities. Choose ‘System Name’ in this list if you do not want, or do
not care about, device name aliases. Do not choose ‘System Name’ if
you are configuring any ‘Name Set Toggle’ buttons.
Multidest Device
Limit
16 (or 8)
This scroll box allows you to specify the maximum number of MD
devices, up to 512. The values increment or decrement by 16 for the
NV9616 and by 8 for the NV9608. The default value is the minimum
value which is 16 for the NV9616 and 8 for the NV9608.
a. See
Defaults