Technical Details
Environmental Specifications
The RS-232 connector has this pinout:
Pins 1, 4, and 6 are tied together and pins 7 and 8 are tied together. None of those pins are
connected to any circuitry.
Environmental Specifications
NV9601 Environmental Specifications
Defaults
Initial Panel State
Multi-destination mode or X-Y mode, selectable.
Destination: the configured default.
Buttons: high-tally is maximum brightness; low-tally is low brightness.
Configuration Page
The default panel options are:
Panel type:
XY/multi-destination mode.
Preset Monitor:
None
Status Monitor:
None
Default mode:
Normal.
Release mode:
Normal.
Default destination:
None.
XY Data Routing:
Automatic.
MD Data Routing:
Automatic.
Default name set:
System names
Multidest Device Limit:
8. (This is the lowest value. The upper limit is 512.)
Use continuous scrolling Enabled (checkbox checked).
All other options:
Disabled (check boxes clear).
n.c.
1
5
9
6
Tx
Rx
Gnd
n.c.
n.c.
n.c.
n.c.
n.c.
Specification
Detail
Operating temperature
0–40 °C, ambient.
Relative humidity
0 to 90%, non-condensing.
Cooling
No fan required.