Software updating procedure – Grass Valley Kameleon HD Multi-Function Modules v.2.5.0 User Manual
Page 107

Kameleon HD—Instruction Manual
107
Software Updating
Software Updating Procedure
To use this method, your 2000NET module must be running version 4.0.0
or later and you must have the NetConfig Networking Application option
running on a networked PC on the same subnet as the frame with the
2000NET module. For acquiring software, refer to
.
Two files types are required for updating software, an .fld and an .sw2 for
the module being updated.
To use NetConfig for software updating, follow the steps below:
1.
Locate the PC directory in which the NetConfig application has been
installed. The default location is C:\Program Files\Grass Valley
Group\NetConfig.
If this is not where NetConfig was installed, right-click on the Net-
Config desktop shortcut and select
Properties
, click on the
Shortcut
tab
and note the location of the installation in the
Start In
field.
2.
Copy the .sw2 file you downloaded into your temporary directory into
the main NetConfig directory. Make sure this file has a .sw2 extension
and not a .txt extension.
3.
Create a subdirectory named
modular
(if one does not already exist) in
the main NetConfig directory.
4.
Copy the .fld file(s) you downloaded into your temporary directory
into this
modular
subdirectory.
5.
Open NetConfig by double-clicking on the NetConfig desktop icon
shown at left.
Note
If you have not used NetConfig before, refer to the NetConfig Instruction
Manual included during installation in the main NetConfig directory in
.PDFpdf format (NetConfig.pdf).
6.
Click on the
Load SW
icon on the top of the NetConfig toolbar (shown at
left).
Note
Different versions of NetConfig may differ in the software update directory
structure used for accessing software. Refer to the NetConfig manual for the
version you are using.