Environmental limits, Life expectancies of components – Grass Valley K2 Level 2 RAID Oct.10 2006 User Manual
Page 62

62
Level 2 RAID Instruction Manual
September 8, 2006
Chapter 4 K2 Level 2 RAID Technical Specifications and Operating Limits
Environmental limits
The system includes two temperature level sensors used to issue auto-warning and
auto-shutdown in case the over temperature limit is reached.
Life expectancies of components
Environmental condition
Operating
Halting
a
a.
The halting status includes the packaged status in shipping carton and the storage status.
Ambient temperature
5°C to 40°C (41°F to 104°F)
-10°C to 60°C (14°F to 140°F)
Relative humidity
10% to 80%
10% to 80%
Wet-bulb temperature
b
b.
Without condensation
0°C to 27°C (32°F to 81°F)
-8°C to 29°C (18°F to 84°F)
Allowable vibration level
0.25 G
0.5 G
Item
Measurement
Battery
2.5 years
Fan (power supply)
50,000 hours