Installing disk module – Grass Valley K2 Level 2 RAID Oct.10 2006 User Manual
Page 49

September 8, 2006
Level 2 RAID Instruction Manual
49
Installing disk module
module number.
2. Remove the disk module as illustrated in the following diagram.
Installing disk module
CAUTION: If the RAID chassis does not have the redundant controller
option, when a replacement disk module is inserted there can be a 1.5
second (maximum) disruption of video (record/play).
To install a disk module:
1. Wait at least three minutes after removing the previous disk module.
2. Put a location label on the replacement disk drive, as appropriate for the slot into
which it is installed.
3. Install the disk module as illustrated in the following diagram.
1
2
3
Pull ejector
out and up
Wait until the
disk stops spinning
(about 30 seconds)
Slide out
!
This manual is related to the following products: