beautypg.com

Controller configuration requirements, Chapter 2 k2 level 2 raid installation information – Grass Valley K2 Level 2 RAID Oct.10 2006 User Manual

Page 26

background image

26

Level 2 RAID Instruction Manual

September 8, 2006

Chapter 2 K2 Level 2 RAID Installation Information

Controller configuration requirements

The default settings for the controller DIP switches are shown in the following
illustrations and table. Remove the controller, as explained in

“Removing a RAID

controller or expansion adapter” on page 50

, and verify that the default settings are

intact.

Switch position

Bit position

Setting position and function

A9E2

1

Fixed to OFF (HDD Spin-up Mode, OFF: Command, ON: Auto)

2

Fixed to ON (Operation Mode, OFF: NF1200, ON: NF1300)

3

OFF by default

(Topology, OFF: FC_AL, ON: Fabric)

4

Fixed to OFF (MD Mode, OFF: Normal, ON: Long MD)

A9E1

5

Fixed to ON

6

Fixed to OFF

7

Fixed to OFF

8

Fixed to OFF

Access DIP switches
from the bottom of the
controller module

4 3 2 1

4 3 2 1

4 3 2 1

1

2

3

4

5

6

7

8

9

A

B

C

OFF

A9D

A9E1

A9E2

Connector on
backboard side
of controller

Verify these settings

This manual is related to the following products: