Controller configuration requirements, Chapter 2 k2 level 2 raid installation information – Grass Valley K2 Level 2 RAID Oct.10 2006 User Manual
Page 26

26
Level 2 RAID Instruction Manual
September 8, 2006
Chapter 2 K2 Level 2 RAID Installation Information
Controller configuration requirements
The default settings for the controller DIP switches are shown in the following
illustrations and table. Remove the controller, as explained in
controller or expansion adapter” on page 50
, and verify that the default settings are
intact.
Switch position
Bit position
Setting position and function
A9E2
1
Fixed to OFF (HDD Spin-up Mode, OFF: Command, ON: Auto)
2
Fixed to ON (Operation Mode, OFF: NF1200, ON: NF1300)
3
OFF by default
(Topology, OFF: FC_AL, ON: Fabric)
4
Fixed to OFF (MD Mode, OFF: Normal, ON: Long MD)
A9E1
5
Fixed to ON
6
Fixed to OFF
7
Fixed to OFF
8
Fixed to OFF
Access DIP switches
from the bottom of the
controller module
4 3 2 1
4 3 2 1
4 3 2 1
1
2
3
4
5
6
7
8
9
A
B
C
OFF
A9D
A9E1
A9E2
Connector on
backboard side
of controller
Verify these settings