Data handling specifications, Ac power requirements, Chapter 4 – Grass Valley K2 10G RAID User Manual
Page 70: Data handling specifications ac power requirements, Chapter 4, k2, Chapter

18 November 2010
K2 10G RAID Storage Instruction Manual
70
Chapter
4
K2 10G RAID Technical Specifications
and Operating Limits
Data handling specifications
AC power requirements
If one of the two power supplies fails, the remaining supply and cord must support the
full load. Your rackmount cabinet must include AC power distribution that can handle
these values.
Characteristic
Specification
Host interface
Fibre Channel
Data transfer rate
800 MB/s max
Number of host ports
2 ports per controller standard. 2 additional ports optional.
Cache memory
8 GB
Item
Measurement
Input voltage
100 to 240 VAC ±10% (x2), 50/60 Hz
Power consumption
a
Power supply
a.
For UPS choice, a safety allowance of 30% of the power consumption is necessary.
Power supply:
Basic cabinet: 2118 BTU/W
Expansion cabinet: 1470 BTU/W
Maximum power consumption
Basic Chassis
SAS
AC: 660VA/640W
SATA
AC: 590VA/570W
Maximum power consumption
Expansion Chassis
SAS
AC: 450VA/430W
SATA
AC: 380VA/370W
Labeling according to the energy
saving act
SAS
Category: i
Energy consumption
rate: AC:0.050
SATA
Category: i
Energy consumption rate:
AC:0.013