beautypg.com

Data handling specifications, Ac power requirements, Chapter 4 – Grass Valley K2 10G RAID User Manual

Page 70: Data handling specifications ac power requirements, Chapter 4, k2, Chapter

background image

18 November 2010

K2 10G RAID Storage Instruction Manual

70

Chapter

4

K2 10G RAID Technical Specifications

and Operating Limits

Data handling specifications

AC power requirements

If one of the two power supplies fails, the remaining supply and cord must support the

full load. Your rackmount cabinet must include AC power distribution that can handle

these values.

Characteristic

Specification

Host interface

Fibre Channel

Data transfer rate

800 MB/s max

Number of host ports

2 ports per controller standard. 2 additional ports optional.

Cache memory

8 GB

Item

Measurement

Input voltage

100 to 240 VAC ±10% (x2), 50/60 Hz

Power consumption

a

Power supply

a.

For UPS choice, a safety allowance of 30% of the power consumption is necessary.

Power supply:
Basic cabinet: 2118 BTU/W
Expansion cabinet: 1470 BTU/W

Maximum power consumption

a.

Basic Chassis

SAS
AC: 660VA/640W

SATA
AC: 590VA/570W

Maximum power consumption

a.

Expansion Chassis

SAS
AC: 450VA/430W

SATA
AC: 380VA/370W

Labeling according to the energy
saving act

SAS
Category: i
Energy consumption
rate: AC:0.050

SATA
Category: i
Energy consumption rate:
AC:0.013