beautypg.com

K2 10g raid power-down – Grass Valley K2 10G RAID User Manual

Page 50

background image

18 November 2010

K2 10G RAID Storage Instruction Manual

50

K2 10G RAID power-down

If the RAID chassis has two controllers, you can press the power button on either

controller. You do not need to press both power buttons.
Pressing the power button on a controller also powers on any connected Expansion

chassis. There are no power buttons on Expansion chassis.

3. Release the power button when the Power Good LED on the power supply is

illuminated. This takes 1-3 seconds.

4. Wait while the primary RAID chassis performs self-test and initialization. This

takes about four minutes. While this is taking place, the RDY LED is illuminated

with a steady on light.

5. Watch for the RDY LED to begin blinking at one second intervals. The LED might

turn off and back on two times before starting the one second blink pattern. When

the RDY LED is blinking at one second intervals, the self-test and initialization is

complete and the chassis is ready for use.
Refer to sections in

Chapter 3, “Servicing the K2 10G RAID”

for information on

interpreting status LED behavior.

NOTE: Refer to the K2 SAN Installation and Service Manual for complete system

power-up procedures.

K2 10G RAID power-down

NOTE: If your K2 10G RAID system is part of a shared storage system, refer to the

K2 SAN Installation and Service Manual

for instructions on shutting down the

shared storage before powering down a K2 10G RAID.

To power-down the K2 10G RAID correctly:

1. Stop all read/write activity to the K2 10G RAID storage system.

2. On the primary RAID controller chassis, press and hold down the power button.

3. Release the power button in about 5 seconds, when the RDY LED blinks more

quickly, at a rate of about 2 blinks per second.

NOTE: Do not hold down the power button for longer than 15 seconds.

The power is turned off for the primary and expansion RAIDs. Power-off normally

occurs within 20 seconds. It is indicated when LEDs other than those on the power

supplies go off and the fans stop rotating.

BBU IN

MODEM

FLT/LNK

HPE

FLT

A/L

BACKUP

ACT/LNK

LNK/ACT

FLT

HP

5 4 3 2

RDY

LAN

BAT

MNT

ACS

MC

DP1

DP0

HP

1 0

BBU IN

MODEM

FLT/LNK

HPE

FLT

A/L

BACKUP

ACT/LNK

LNK/ACT

FLT

HP

5 4 3 2

RDY

LAN

BAT

MNT

ACS

MC

DP1

DP0

HP

1 0

Power Cords

(115V/230V)

RDY
LED

RDY
LED

Power Good

LED

Power Good

LED