Binding disk modules into groups, Installing a k2 10g raid in an equipment rack, Unpacking the chassis – Grass Valley K2 10G RAID User Manual
Page 41: Installing the rack mounts, Unpacking the chassis installing the rack mounts

41
K2 10G RAID Storage Instruction Manual
18 November 2010
Chapter 2 K2 10G RAID Installation Information
Binding disk modules into groups
After cabling a K2 10G RAID and any K2 10G Expansion Chassis, you must bind
disk modules using the Storage Utility provided by Grass Valley. Once bound, the
order of the drives is important. Do not rearrange drives once they have been bound.
Refer to the K2 SAN Installation and Service Manual for information on using the
Storage Utility to bind drives.
Installing a K2 10G RAID in an equipment rack
Use the information in this section to unpack the K2 10G RAID chassis and mount in
an equipment rack.
Procedures include:
•
•
•
“Inserting the K2 10G RAID chassis in the rack”
Unpacking the chassis
Unpack the K2 10G RAID chassis, cables, and installation kit, as illustrated by the
diagram on the outside of the packing box.
CAUTION: A K2 10G RAID chassis is heavy. Three people
should lift and move it.
NOTE: Save the chassis packaging. Use only K2 approved packaging to ship.
Installing the rack mounts
The rack kit consists of left side rail and right side rail. The rack kit has Guide
Brackets as follows:
• H — For racks with 0.281 inch round holes
• T — For racks with No. 10-32 UNF threaded holes
These instructions apply to the left side rack. Install as directed, then apply similarly
to the right side rack.
1. Stand facing the front of the rack to orient right and left sides.
2. Identify right side and left side rails as follows:
• The right side rail has an installation diagram affixed. When installed correctly,
this diagram faces the outside of the rack.
• The left side rail has no diagram affixed.
!