If additional criteria are required (such as excluding clips that are recording) you can
change this default string. To change the criteria:
a Click the ellipsis button next to the Creatable field. The PinPoint window
appears.
b Click + next to the first criterion to add another row.
c Enter your required criterion. For example, to prevent media that is recording from
being manually archived, for the first value select
Media
>
Recording
, then for the
second value select
No
.
d To add another criterion click + on the last row.
e When you have finished adding criteria, click OK. The PinPoint window closes.
4 Specify the workflow properties:
a Click Properties. The Workflow Properties Editor... appears.
b Right click on a blank row and select Add property. The Add New Property...
dialog appears.
c Set the properties details as follows:
• In the Name field type
ARCHIVE
• In the Type drop down list select
string
• In the Value field type the name of the endpoint in Delivery Manager (e.g.
DIVArchive
or
FlashNet
).
d Click OK. The Workflow Property Editor window closes.
5 Click Save. The Workflow Configuration window closes.
6 Restart the Workflow Service. See
on page 53 for more
information.
7 If you have changed the name of the Workflow, you must also restart the iTX Desktop
or reload the SmartClient in your browser in order for the new name to appear on the
corresponding button.
Configuring a Manual Restore workflow
For a Manual Restore operation, the workflow needs the media archive location type. This
will usually be a third party archiving system such as DIVA, so you would need to include
MediaLocationType
is
Archive
in the Creatable criteria.
To add a DIVArchive location type to the Creatable criteria:
1 Open Workflow Configuration and go to the Simple tab.
2 From the Simple Workflows list, select the Manual Restore.
3 Click the ellipsis button next to the Creatable field. The PinPoint window appears,
showing the current criteria.