Configure the default opus store, Configure diva for partial restores – Grass Valley iTX Delivery Manager v.2.6 User Manual
Page 35

29
Delivery Manager
Configuration and Setup Guide
Configure the default Opus store
Delivery Manager requests that the media be restored to the Opus Admin Default Store, so if you
are adding multiple stores to DIVA, the Opus Admin Default must be one of the stores you add.
Note:
Delivery Manager's endpoint passes a restore request to DIVA using
the default store name, so the
Source Name
in DIVA must match the name
in the
Store
field in Opus.
You configure which store is the default store for Opus to use via the iTX Desktop's
Engineering layout.
To configure the default Opus store from the Engineering layout:
1 Open the iTX Desktop Client and select the Engineering layout.
2 In the System Admin section, click Opus Admin.
3 In the Store Management section, select the store from the Store drop down dialog:
4 Check Default Store.
5 On the Opus Admin window, click Save, then Close.
Configure DIVA for partial restores
Because the DIVArchive Manager software can only read embedded time codes (such as time of
day or feeds recorded with a start time of 10:00:00:00) from some file formats, a configuration file
(called
PartialRestore.conf
)
found in the DIVA Actor directory must be edited to instruct
DIVA to ignore the original time codes associated with the asset and calculate the Co-reference
clip in and out points as if they start from 0.
Note:
This is currently restricted to Quicktime MOV file formats, both self-
contained and referenced based types.