beautypg.com

Adding masstech endpoints – Grass Valley iTX Delivery Manager v.2.6 User Manual

Page 38

background image

32

Adding 3rd Party Endpoints

Adding MassTech Endpoints

15 In the Diva Archive Configuration section, complete the following as required:

Setting

Description

Allow Overwriting
Archive

When moving an asset to the archive, this checkbox allows
overwriting of an asset if it already exists on the DIVA.
If not enabled then archive jobs will fail if the object already exists
on the DIVA in the category of the endpoint.

Monitor DIVA for
Changes

If this checkbox is enabled, the endpoint regularly checks the DIVA
for objects in the category of that endpoint that have been
created, modified, or deleted and update iTX accordingly.

The status of the connection to the DIVA of each endpoint is
checked every 30 seconds. If the connection is lost, the health
indicator turns red for the endpoint on the Delivery Manager
Service.
It automatically tries to reconnect to the DIVA. If the
connection is re-established, the status light returns to green.

Max Concurrent

Jobs

The highest number of jobs that are allowed to run

simultaneously from that endpoint.

Manager IP

Address

The IP address of the DIVArchive Manager Server.

Port

The TCP/IP Port that the endpoint communicates with the

archive on.

16 Click Save then Close.

17 Restart the Delivery Manager service. See

Restarting an iTX Service

on page 53 for

more information.

18 Finalize the Delivery Manager setup:

• To use a DIVA endpoint in Search Media mode, you must also complete the steps

described in

Additional Setup for Search Media mode

, on page 59.

• To use a DIVA endpoint in manual mode, you must also complete the steps

described in

Additional Setup for Manual/Export Mode

, on page 61.

Adding MassTech Endpoints

MassTech endpoints are able to operate in Content Change and Search Media, depending
on whether or not certain workflows are selected during the configuration.

IMPORTANT

You should not attempt to operate a single endpoint configuration in more
than one mode. For example, if you are using the MassTech archive in
Content Change mode you should select a

Content Changed Workflow

and not select a

Cache Content Workflow

within the same configuration

profile.