Configuration parameters – Grass Valley 8977AP-4B User Manual
Page 61
8977AP-4B/4U — Instruction Manual
61
Configuration Parameters
This appendix provides a complete summary of the 8977AP functions and
a comparison of the functionality available with the web page and Newton
control panel control type along with the ranges and default values for each
parameter in
.
Table 5. 8977AP Configuration Parameters
Description
Default
Range/choices
resolution
Web Page / Function
Name
Newton Control
Panel
Drive Frame Reference Bus
Auto
Auto/OFF
Genlock
GLBusDrv
Input Standard
Status
NTSC,
PAL,
1080i/59.94,
1080i/50,
720p/50,
720p/59.94,
1080p/24,
1080sf/24,
AES48K,
AES96K,
Word Clock 48K,
Word Clock 96K
Genlock
GLInStd
Genlock
Enable
Enable or Freerun
Genlock
GLEnable
Input Standard Selection
NTSC
NTSC,
PAL,
1080i/59.94,
1080i/50,
720p/50,
720p/59.94,
1080p/24,
1080sf/24,
AES48K,
AES96K,
Word Clock 48K,
Word Clock 96K
Genlock
GLInSEl
Loop Bandwidth
Fast Lock
Fast Lock / Low Jitter
Genlock
GLLoopBW
Line Offset
0
[0 - 624]
Genlock
GLLnOff
Coarse Offset
0
[0 - 1727]
Genlock
GLcors
Fine Offset
0
[0 - 255]
Genlock
GLfine
Genlock
Status
Freerun / Enabled
Genlock
GLstatus
Input Frame Rate
Status
29.97 / 25 / 24 / 48 /
0 / 96
Genlock
GLInFR
Status
Status
Freerun / Invalid / Locked
Genlock
GLStat
Output Bus
Status
Ref 2 / Ref 1 / Local
Genlock
GLOutBus
Output Frame Rate
Status
29.97 / 25 / 0
Genlock
GLOutFR
Switch to Primary Ref
-
Switching
System Config
Sw2PriRef
Switch Back After Primary Restored
Auto
Auto / Manual
System Config
RefSwBk