beautypg.com

Genlock web page – Grass Valley 8977AP-4B User Manual

Page 49

background image

8977AP-4B/4U — Instruction Manual

49

Remote Configuration

Genlock Web Page

The Genlock web page (

Figure 32 on page 51

) is present on 8977AP controls

when an 8900GEN-SM submodule is installed on the module.

Refer to the 8900GEN-SM Installation Manual available online for complete
details for configuring the 8900GEN-SM submodule.

This web page provides reporting status for the following genlock status
items:

Genlock

– reports status of Genlock function as

Enabled

or

Freerun

.

Status

– reports whether the reference input is

Locked

or

Not Locked

.

Firmware Version

– reports the firmware version of the 8900GEN-SM sub-

module installed on this 8977AP module.

Hardware Revision

– reports the hardware revision of the 8900GEN-SM

submodule installed on this 8977AP module.

Ref Input Standard

– reports the reference input standard as detected by

the 8900GEN-SM submodule that is connected to the Genlock BNC on
the rear module.

The input standards are NTSC, PAL, 1080i/59.94, 720p/59.94, 1080i/50,
720p/50, 1080p/24, 1080sF/24, AES 48K, AES 96K, Word Clock 48K, or
Work Clock 96K.

Output Bus Frame Rate

– reports the frame rate being output on the frame

bus.

Note

The Output Bus Frame Rate is always reported as an SD frame rate for all
input reference standards including audio.

Output Bus

– reports the reference bus (Ref Bus 1 or Ref Bus 2) being

output from the submodule.

Genlock Control

The Genlock submodule may be configured with the following controls:

Genlock

– select one of the radio buttons to

Enable

or

Freerun

(not locked

to external reference).

I

nput Standard Selection

– use this control to set the input standard needed

for the reference input.

Loop Bandwidth

– set the loop bandwidth to

Low Jitter

or

Fast Lock

depending on the type of reference input.

For example, if

Low Jitter

is selected and the Status is still

Invalid

after one

minute has passed, the input reference has excessive wander that
cannot be tracked in

Low Jitter

mode. Switch to

Fast Lock

and verify Status

is Locked after about 10 seconds.