beautypg.com

Service, Power-up diagnostics failure, Troubleshooting – Grass Valley 8977AP-4B User Manual

Page 58: Electronic circuit breaker, Table of alarms

background image

58

8977AP-4B/4U — Instruction Manual

Service

Service

The 8977AP modules make extensive use of surface-mount technology and
programmed parts to achieve compact size and adherence to demanding
technical specifications. Circuit modules should not be serviced in the field
unless otherwise directed by Customer Service.

Power-up Diagnostics Failure

If the module has not passed self-diagnostics, do not attempt to trouble-
shoot. Return the unit to Grass Valley (see

Module Repair on page 59

).

Troubleshooting

Electronic Circuit Breaker

The electronic circuit breaker works during a fault condition or an overcur-
rent which stops the module.

Remove the module and replace it in the frame. If the problem persists,
please contact Grass Valley Customer Service with the contacts given on

page 4

.

Table of Alarms

Table 4

describes the different type of alarms generated on the module.

Table 4. List of Alarms for 8977AP Module

Alarm

type

Web Page Description

LED

Status

Comments

Status

reported

to the

8900Net

&SNMP

Pass

Genlock module is not installed

Green

Genlock missing

No

Fault

Genlock submodule failed, replace

Red

Genlock Failure

No

Fault

Power supply bad

Red

Problem of power supply

Yes

Fault

FPGA failure

Red

FPGA not loaded

Yes

Warning

Wrong Rear Module (incompatible with 8977AP-4U)

Yellow

Rear module is different of 8900UE-R

Yes

Warning

Wrong Rear Module (incompatible with 8977AP-4B)

Yellow

Rear module is different of 8900BA-R

Yes

Warning

Ref 1 is Not Present

Yellow

Ref 1 from FrameRef 1 is missing

Yes

Warning

Ref 2 is Not Present

Yellow

Ref 2 from FrameRef 2 is missing

Yes

Warning

Local Ref is Not Present

Yellow

Input ref is not detected

Yes

Warning

Redundant Ref in Not Present

Yellow

The second ref selected is missing

Yes

Warning

Audio Input: AES 1 Input Signal Not Detected

Yellow

No AES 1 input detected

Yes

Warning

Audio Input: AES 2 Input Signal Not Detected

Yellow

No AES 2 input detected

Yes

Warning

Audio Input: AES 3 Input Signal Not Detected

Yellow

No AES 3 input detected

Yes